LHB TL & AC MCQ (191-210) |
- How much is set for the High-Water Temperature INTAC Engine?
- 100 ºC
- 107 ºC
- 110 ºC
- 115 ºC
Show Answer
Correct Answer » 107 ºC
- How much is set for the High-Water Temperature CUMMINS Engine?
- 90 ºC
- 95 ºC
- 97 ºC
- 100 ºC
Show Answer
Correct Answer » 97 ºC
- Which type of Fire extinguishers is used in the power car?
- Soda Acid type
- Water Foam based type.
- Dry Powder Type
- C.T.C & CO2 type
Show Answer
Correct Answer » Dry Powder Type
- Which capacity fuses are used for the protection of the incoming side of 750 volts in LHB?
- 3 x 60 A HRC fuses
- 3 x 63 A HRC fuses
- 3 x 65 A HRC fuses
- Incoming feeder directly on the contactors
Show Answer
Correct Answer » 3 x 63 A HRC fuses
- Which capacity fuses are used for the protection of the incoming side of 415 volts?
- 3 x 60 A HRC fuses
- 3 x 70 A HRC fuses
- 3 x 80 A HRC fuses
- 3 x 100 A HRC fuses
Show Answer
Correct Answer » 3 x 100 A HRC fuses
- What is the Coach length of the LHB power car?
- 23.3 meters
- 23.5 meters
- 23.8 meters
- 24.0 meters
Show Answer
Correct Answer » 23.5 meters
- What are the Dimensions of Hot case provided in mini pantry of coaches?
- 900 x 1050 x 600 mm
- 900 x 1050 x 605 mm
- 910 x 1092 x 600 mm
- 950 x 1092 x 600 mm
Show Answer
Correct Answer » 910 x 1092 x 600 mm
- What is the operating volt of hot case provided in mini pantry of coaches?
- 110 Volt
- 230 Volt
- 415 Volt
- 110 Volt DC
Show Answer
Correct Answer » 230 Volt
- What is the capacity of the Heating element of hot case provided in the mini pantry of coaches?
- 3 x 500 Watt or 2 x 500 watt
- 750 Watt
- 1800 Watt
- 2000 Watt
Show Answer
Correct Answer » 3 x 500 Watt or 2 x 500 watt
- What is the Operating temperature of hot case provided in the mini pantry of coaches?
- 60 ºC
- 70 ºC
- 80 ºC
- 90 ºC
Show Answer
Correct Answer » 80 ºC
- What is the range of the Thermostat of Hot case provided in the mini pantry of coaches?
- 30 – 80° C
- 40 – 80° C
- 50 – 80° C
- 60 – 80° C
Show Answer
Correct Answer » 30 – 80° C
- What are the Dimensions of Refrigerating Unit provided in mini pantry of coaches?
- 1100 x 595 x 1195 mm
- 1157 x 550 x 1195 mm
- 1157 x 595 x 1195 mm
- 1157 x 595 x 1150 mm
Show Answer
Correct Answer » 1157 x 595 x 1195 mm
- What is the power of the Refrigerating Unit provided in the mini pantry of coaches?
- 500 Watt
- 600 Watt
- 700 Watt
- 800 Watt
Show Answer
Correct Answer » 800 Watt
- What is the Refrigeration capacity of the Refrigerating Unit provided in the mini pantry of coaches?
- 550 kCal/Hr.
- 560 kCal/Hr.
- 570 kCal/Hr.
- 580 kCal/Hr.
Show Answer
Correct Answer » 560 kCal/Hr.
- Which Refrigerant is used in the Refrigerating Unit provided in the mini pantry of coaches?
- R11
- R12
- R22
- R32
Show Answer
Correct Answer » R22
- What is the Thermostat range of the Deep freezer provided in the mini pantry of coaches?
- -18 to -25°C
- -20 to -25°C
- -20 to -30°C
- -22 to -25°C
Show Answer
Correct Answer » -18 to -25°C
- What is the Thermostat range of the Bottle cooler provided in the mini pantry of coaches?
- 2 to + 10°C
- 3 to + 5°C
- 0 to + 05°C
- 3 to + 15°C
Show Answer
Correct Answer » 3 to + 5°C
- What is the capacity of the Bottle cooler provided in the mini pantry of coaches?
- 70 Bottle of 1.0 liter
- 80 Bottle of 1.0 liter
- 90 Bottle of 1.0 liter
- 100 Bottle of 1.0 liter
Show Answer
Correct Answer » 90 Bottle of 1.0 liter
- What is the Thermostat range of the Cooling compartment of the Refrigerating Unit provided in the mini pantry of coaches?
- 0 to + 03°C
- 0 to + 05°C
- 0 to + 10°C
- 0 to + 15°C
Show Answer
Correct Answer » 0 to + 10°C
- What are the Dimensions of the Bottle Cooler provided in the mini pantry of coaches?
- 900x600x900
- 910x620x900 mm
- 910x600x940 mm
- 910x600x900 mm
Show Answer
Correct Answer » 910x600x900 mm
LHB TL & AC MCQS |
- LHB TL & AC MCQ (1-15)
- LHB TL & AC MCQ (16-30)
- LHB TL & AC MCQ (31-45)
- LHB TL & AC MCQ (46-60)
- LHB TL & AC MCQ (61-75)
- LHB TL & AC MCQ (76-90)
- LHB TL & AC MCQ (91-105)
- LHB TL & AC MCQ (106-120)
- LHB TL & AC MCQ (121-135)
- LHB TL & AC MCQ (136-150)
- LHB TL & AC MCQ (151-170)
- LHB TL & AC MCQ (171-190)
- LHB TL & AC MCQ (191-210)
- LHB TL & AC MCQ (211-230)
- LHB TL & AC MCQ (231-250)
- LHB TL & AC MCQ (251-270)
- LHB TL & AC MCQ (271-285)