LHB TL & AC MCQ (151-170) |
- What is the capacity of roof mounted AC unit in a power car?
- 1×6 Ton
- 2×6 Ton
- 1×7 Ton
- 2×7 Ton
Show Answer
Correct Answer » 1×7 Ton
- How many Power Transformers provided in the power car?
- 1
- 2
- 3
- 4
Show Answer
Correct Answer » 3
- What is the capacity of Transformers provided in the power car?
- 60 kVA, Star- Delta
- 60 kVA, Star -Star
- 60 kVA, Delta -Delta
- 60 kVA, Delta- Star
Show Answer
Correct Answer » 60 kVA, Star -Star
- What is the input Voltage of Transformers?
- 750 Volts, 3Phase
- 415 Volts, 3Phase
- 215 Volts, 1Phase
- None
Show Answer
Correct Answer » 750 Volts, 3Phase
- What is the output Voltage of Transformers?
- 750 Volts, 3Phase
- 415 Volts, 3Phase
- 215 Volts, 1Phase
- None
Show Answer
Correct Answer » 415 Volts, 3Phase
- How many DG set provided in the power car?
- 1
- 2
- 3
- 4
Show Answer
Correct Answer » 2
- What is the capacity of the DG Set Engine?
- 450 BHP
- 470 BHP
- 496 BHP
- 500 BHP
Show Answer
Correct Answer » 496 BHP
- What is the capacity of the DG Set Alternator?
- 300 kVA at NTP
- 400 kVA at NTP
- 500 kVA at NTP
- 600 kVA at NTP
Show Answer
Correct Answer » 500 kVA at NTP
- What is the output Voltage of the Alternator?
- 190 Volts, Single Phase, 2 wires
- 230 Volts, Single Phase, 2 wires
- 415 Volts, 3 Phase, 4 wires
- 750 Volts, 3 Phase, 4 wires
Show Answer
Correct Answer » 750 Volts, 3 Phase, 4 wires
- What is the Rating of the Air-Circuit breaker used for Alternator output?
- 410 amps
- 520 amps
- 610 amps
- 800 amps
Show Answer
Correct Answer » 800 amps
- What is the Rating of feeder contactor used in LHB Power car?
- 400 amps
- 520 amps
- 630 amps
- 800 amps
Show Answer
Correct Answer » 630 amps
- In LHB Power Car NWP contactor means?
- Non-Working Power Car contactor
- New working power contactor
- Network power contactor
- None
Show Answer
Correct Answer » Non-Working Power Car contactor
- What is AVR means in LHB Power Car?
- Automatic variable regulator
- Automatic voltage regulator
- Anti vibration regulator
- None
Show Answer
Correct Answer » Automatic voltage regulator
- How many Diesel tanks provided in the LHB Power Car?
- 1 no.
- 2 nos.
- 3 nos.
- 4 nos.
Show Answer
Correct Answer » 2 nos.
- What is the total capacity of the Diesel tank provided in the LHB Power Car?
- 1500 liters
- 2000 liters
- 2500 liters
- 3000 liters
Show Answer
Correct Answer » 3000 liters
- What is the capacity of each Diesel tank in the LHB Power Car?
- 1500 liters
- 2000 liters
- 2500 liters
- 3000 liters
Show Answer
Correct Answer » 1500 liters
- How much Water storage tank provided?
- 1 x 685 litres
- 2 x 685 litres
- 1 x 650 litres
- 1 x 665 litres
Show Answer
Correct Answer » 1 x 650 litres
- What is the capacity of the DG Set Radiator fan?
- 30 HP
- 40 HP
- 50 HP
- 60 HP
Show Answer
Correct Answer » 40 HP
- What is the input Voltage for the DG Set Radiator fan motor?
- 750 Volts, 3Phase
- 415 Volts, 3Phase
- 215 Volts, 1Phase
- None
Show Answer
Correct Answer » 415 Volts, 3Phase
- What should be used in radiators for cooling of the D G set?
- Ordinary Water
- Distilled Water
- Coolants
- None
Show Answer
Correct Answer » Coolants
LHB TL & AC MCQS |
- LHB TL & AC MCQ (1-15)
- LHB TL & AC MCQ (16-30)
- LHB TL & AC MCQ (31-45)
- LHB TL & AC MCQ (46-60)
- LHB TL & AC MCQ (61-75)
- LHB TL & AC MCQ (76-90)
- LHB TL & AC MCQ (91-105)
- LHB TL & AC MCQ (106-120)
- LHB TL & AC MCQ (121-135)
- LHB TL & AC MCQ (136-150)
- LHB TL & AC MCQ (151-170)
- LHB TL & AC MCQ (171-190)
- LHB TL & AC MCQ (191-210)
- LHB TL & AC MCQ (211-230)
- LHB TL & AC MCQ (231-250)
- LHB TL & AC MCQ (251-270)
- LHB TL & AC MCQ (271-285)